| Test Error Codes (1) , (2) | Mod | Code | Problem | Could be |
| Belt replacement | from the back panel. Not from | |||
| ASKO | ||||
| Frigidaire | Electrical Gas Wiring | |||
| GE stackable | DSXH47EG1WW | : test heater: Yl [motor block terminal]_ Bl [2 wire connector to MB]=11_15Ω | ||
| GE | 3 stars screw | Heater | WH_orther color (opposite side) of a 4 terminal sensor [42Ω] connecting to High Limit T'stat, under 37Ω=> bad. This model has heater with double coils [42Ω=21Ω*2]. cost $85 for heater. Move drum forward to get the drum out. | |
| Fisher Paykel | Top load dryer | Run | Not heating | pry 2 small plastic knobs both side, release 4 screws, press reset red switch at bottom. Try, not working, continue check other elements |
| LG manual | Not turn on but interior light: check T'stat fuse, door switch, ctrl board. | |||
| Maytag Performa | Old | No power | Thermo fuse closed to heater or Timer | |
| KM new model | Turning+not heat: T'stats, heater are OK=> Contrl board is bad | |||
| KM Stackable | Wiring | |||
| Sears/Kenmore HE3_ F01 Error code | Bad board: soldering between relay (bad pin) and K2 (good pin) | |||
| WP Duet | Remove ctrl panel: release 4 screws in the back; Remove drum: release one side of cabinet | |||
| Motor not working+Not heating+Counting down: fuse, Control board | ||||
| WP electric | Most new model | Thermal fuse is wired in series with drive motor, wiring, Motor test FrontlintWiring, Motortest2, W10436308.pdf Analog Timer Timer WPW10185982 | ||
| Count down, not run=> fuse, contrl board, motor; | ||||
| WP F01 Error | ||||
| WP electric old model | Not heat: check timer: BK_BU/BK_RD must be continuity, The last is dryness ctrl board (2 resistors look bad color 8558178) | |||
| WP electric | Autodry not move: | 240v inlet at dryer motor=>Tmer OK, Cycling T'stat bad or vice versa | ||
| Frigidaire gas | Sequences: Cạch rất lớn igniter turn on, Cạch gas on, cạch gas off | |||
| WP gas | KenmoreEllit, Amiral | Not heating | (1))Gas valve solenoids: 2 pin=[1kΩ_ 2kΩ]; 3 pin=> 1_3=[500_1kΩ]; 1_2[1.3KΩ]; (2) Flame sensor= 0Ω; igniter [60Ω]; 2 wire coming down=110V; Heater Relay on ctrl panel, Circuit Board, Timer, Thermal fuse ( is wired series with gas valve, wiring) | |
| SS Electric | Access: Top panel, pry and lift up out the display screen, remove two screws outside in lint filter, lift up the door out and lay on top. | |||
| SS Electric | Not run, Power ok | : Thermostat on blower, motor safety switch, Control board, | ||